| Thickness [mm] | Width [mm] | Thickness tolerances [mm] | |
|---|---|---|---|
| acc. to EN 1758 |
restricted values |
||
| >0,2 -<0,50 |
<120 |
+/- 0,008 |
+/- 0,005 |
| 0,50 -<0,80 |
<120 |
+/- 0,013 |
+/- 0,005 |
| 0,80 -<1,00 |
<120 |
+/- 0,015 | +/- 0,008 |
| 1,00 -<1,50 | <120 |
+/- 0,020 |
+/- 0,010 |
| 1,50 -<2,10 |
<120 |
+/- 0,025 |
+/- 0,010 |
| 2,10 -<3,00 |
<120 |
- | +/- 0,050 |
| Thickness [mm] | Width tolerance for strip widths | |||
|---|---|---|---|---|
| over |
up to |
up to 50 |
over 50 up to 100 |
over 100 up to 200 |
| 0,10 | 1,0 | + 0,20 -0 |
+ 0,30 -0 |
+ 0,40 -0 |
| 1,0 | 2,0 | + 0,30 -0 |
+ 0,40 -0 |
+ 0,50 -0 |
| 2,0 | 2,5 |
+ 0,50 -0 |
+ 0,60 -0 |
+ 0,70 -0 |
| 2,5 |
3,0 |
+ 1,0 -0 |
+ 1,10 -0 |
+ 1,20 -0 |
| 3,0 |
4,0 | + 2,00 -0 |
+ 2,30 -0 |
+ 2,50 -0 |
| *reduced values on request | |||
| Roughness [10 -3mm] | |||
|---|---|---|---|
| Standard values |
Reduced values* | ||
| Ra |
Rmax |
Ra |
Rmax |
| <=0,20 |
<=2,0 | <=0,16 |
<=1,5 |
| *reduced values on request | |
| Roughness [10 -3mm] | |
|---|---|
| Standard values |
Reduced values* |
| Ra |
Ra |
| <=0,4 |
<=0,2 |